{"product_id":"shape-tactics-cryotherapy-40k-cavitation-rf-contouring-system","title":"Shape Tactics Cryotherapy 40K Cavitation \u0026 RF Contouring System","description":"\u003cdiv data-testid=\"conversation-turn-5\"\u003e\n\u003cdiv data-message-author-role=\"assistant\" data-message-id=\"bcfebf76-2292-4e83-9868-a5e2f99b94c4\"\u003e\n\u003cp data-start=\"257\" data-end=\"597\"\u003eThe Shape Tactics Cryotherapy 40K Cavitation \u0026amp; RF Contouring System integrates controlled cooling, ultrasonic cavitation, radio frequency (RF), and vacuum therapy to support body sculpting and skin firming. This non-invasive system is designed for customized treatments, offering a versatile approach for both professional and personal use.\u003c\/p\u003e\n\u003cp data-start=\"599\" data-end=\"1001\"\u003eThe cooling vacuum handle provides targeted temperature control (5°C to -5°C) for a comfortable contouring experience. The 40K ultrasonic cavitation handle delivers focused sound wave energy, while RF therapy and vacuum technology enhance skin elasticity and circulation. With adjustable settings and a multi-functional approach, this system offers a complete solution for body and facial applications.\u003c\/p\u003e\n\u003cp data-start=\"1003\" data-end=\"1022\"\u003e\u003cstrong data-start=\"1003\" data-end=\"1022\"\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1023\" data-end=\"1673\"\u003e\n\u003cli data-start=\"1023\" data-end=\"1128\"\u003e\n\u003cp data-start=\"1025\" data-end=\"1038\"\u003ePower Supply:\u003c\/p\u003e\n\u003cul data-start=\"1041\" data-end=\"1128\"\u003e\n\u003cli data-start=\"1041\" data-end=\"1099\"\u003e\n\u003cp data-start=\"1043\" data-end=\"1099\"\u003eRated Input Voltage: AC220V-240V 50Hz \/ AC110V-120V 60Hz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1102\" data-end=\"1128\"\u003e\n\u003cp data-start=\"1104\" data-end=\"1128\"\u003eRated Input Power: 350VA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1129\" data-end=\"1270\"\u003e\n\u003cp data-start=\"1131\" data-end=\"1153\"\u003eCooling Vacuum System:\u003c\/p\u003e\n\u003cul data-start=\"1156\" data-end=\"1270\"\u003e\n\u003cli data-start=\"1156\" data-end=\"1175\"\u003e\n\u003cp data-start=\"1158\" data-end=\"1175\"\u003ePower: Up to 200W\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1178\" data-end=\"1211\"\u003e\n\u003cp data-start=\"1180\" data-end=\"1211\"\u003eOutput Temperature: 5°C to -5°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1214\" data-end=\"1239\"\u003e\n\u003cp data-start=\"1216\" data-end=\"1239\"\u003eVacuum Pressure: 0-5Kpa\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1242\" data-end=\"1270\"\u003e\n\u003cp data-start=\"1244\" data-end=\"1270\"\u003eCooling Liquid: Pure Water\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1271\" data-end=\"1371\"\u003e\n\u003cp data-start=\"1273\" data-end=\"1295\"\u003eUltrasonic Cavitation:\u003c\/p\u003e\n\u003cul data-start=\"1298\" data-end=\"1371\"\u003e\n\u003cli data-start=\"1298\" data-end=\"1316\"\u003e\n\u003cp data-start=\"1300\" data-end=\"1316\"\u003eFrequency: 40KHz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1319\" data-end=\"1337\"\u003e\n\u003cp data-start=\"1321\" data-end=\"1337\"\u003ePower: Up to 60W\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1340\" data-end=\"1371\"\u003e\n\u003cp data-start=\"1342\" data-end=\"1371\"\u003eCavitation Tip Diameter: 60mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1372\" data-end=\"1673\"\u003e\n\u003cp data-start=\"1374\" data-end=\"1405\"\u003eRF Therapy \u0026amp; Vacuum Technology:\u003c\/p\u003e\n\u003cul data-start=\"1408\" data-end=\"1673\"\u003e\n\u003cli data-start=\"1408\" data-end=\"1474\"\u003e\n\u003cp data-start=\"1410\" data-end=\"1429\"\u003eOctupole RF (Body):\u003c\/p\u003e\n\u003cul data-start=\"1434\" data-end=\"1474\"\u003e\n\u003cli data-start=\"1434\" data-end=\"1451\"\u003e\n\u003cp data-start=\"1436\" data-end=\"1451\"\u003eFrequency: 3MHz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1456\" data-end=\"1474\"\u003e\n\u003cp data-start=\"1458\" data-end=\"1474\"\u003ePower: Up to 30W\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1477\" data-end=\"1605\"\u003e\n\u003cp data-start=\"1479\" data-end=\"1512\"\u003eSextupolar RF with Vacuum (Body):\u003c\/p\u003e\n\u003cul data-start=\"1517\" data-end=\"1605\"\u003e\n\u003cli data-start=\"1517\" data-end=\"1534\"\u003e\n\u003cp data-start=\"1519\" data-end=\"1534\"\u003eFrequency: 1MHz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1539\" data-end=\"1551\"\u003e\n\u003cp data-start=\"1541\" data-end=\"1551\"\u003ePower: 50W\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1556\" data-end=\"1581\"\u003e\n\u003cp data-start=\"1558\" data-end=\"1581\"\u003eVacuum Pressure: ≤80kPa\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1586\" data-end=\"1605\"\u003e\n\u003cp data-start=\"1588\" data-end=\"1605\"\u003ePressure: \u0026gt;250kPa\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1608\" data-end=\"1673\"\u003e\n\u003cp data-start=\"1610\" data-end=\"1628\"\u003eBipolar RF (Face):\u003c\/p\u003e\n\u003cul data-start=\"1633\" data-end=\"1673\"\u003e\n\u003cli data-start=\"1633\" data-end=\"1650\"\u003e\n\u003cp data-start=\"1635\" data-end=\"1650\"\u003eFrequency: 3MHz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1655\" data-end=\"1673\"\u003e\n\u003cp data-start=\"1657\" data-end=\"1673\"\u003ePower: Up to 30W\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1675\" data-end=\"1696\"\u003e\u003cstrong data-start=\"1675\" data-end=\"1696\"\u003ePackage Contents:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1697\" data-end=\"1924\"\u003e\n\u003cli data-start=\"1697\" data-end=\"1714\"\u003e\n\u003cp data-start=\"1699\" data-end=\"1714\"\u003e1x Main Machine\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1715\" data-end=\"1741\"\u003e\n\u003cp data-start=\"1717\" data-end=\"1741\"\u003e1x Cooling Vacuum Handle\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1742\" data-end=\"1770\"\u003e\n\u003cp data-start=\"1744\" data-end=\"1770\"\u003e1x 40KHz Cavitation Handle\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1771\" data-end=\"1799\"\u003e\n\u003cp data-start=\"1773\" data-end=\"1799\"\u003e1x Body Octupole RF Handle\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1800\" data-end=\"1842\"\u003e\n\u003cp data-start=\"1802\" data-end=\"1842\"\u003e1x Body Sextupolar RF with Vacuum Handle\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1843\" data-end=\"1870\"\u003e\n\u003cp data-start=\"1845\" data-end=\"1870\"\u003e1x Face Bipolar RF Handle\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1871\" data-end=\"1892\"\u003e\n\u003cp data-start=\"1873\" data-end=\"1892\"\u003e1x Accessory Holder\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1893\" data-end=\"1908\"\u003e\n\u003cp data-start=\"1895\" data-end=\"1908\"\u003e1x Key Switch\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1909\" data-end=\"1924\"\u003e\n\u003cp data-start=\"1911\" data-end=\"1924\"\u003e1x Power Cord\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Cavitation Machines","offers":[{"title":"Default Title","offer_id":52932497310005,"sku":"MSCM7007F","price":3102.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/3293\/2661\/files\/shape-tactics-cryolipolysis-40k-cavitation-rf-body-contouring-system-mscm7007f-610708.jpg?v=1779904402","url":"https:\/\/rewellmarketplace.com\/products\/shape-tactics-cryotherapy-40k-cavitation-rf-contouring-system","provider":"ReWell Marketplace","version":"1.0","type":"link"}